ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2009;9:893-895. doi:10.1510/icvts.2009.215152
© 2009 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Karl G. Reyes
Gosta B. Pettersson
Tomislav Mihaljevic
Eric E. Roselli
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Reyes, K. G.
Right arrow Articles by Roselli, E. E.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reyes, K. G.
Right arrow Articles by Roselli, E. E.
Related Collections
Right arrow Cardiac - other
Right arrow Great vessels
Right arrow Valve disease

Case report - Cardiac general

A strategy for safe sternal reentry in patients with pseudoaneurysms of the ascending aorta using the PORT-ACCESS EndoCPB system

Karl G. Reyes, Gosta B. Pettersson*, Tomislav Mihaljevic and Eric E. Roselli

Departments of Thoracic and Cardiovascular Surgery, Cleveland Clinic, Cleveland, OH, USA

Received 26 June 2009; received in revised form 14 August 2009; accepted 18 August 2009

*Corresponding author. 9500 Euclid Avenue/J4-100, Cleveland, OH 44195, USA. Tel.: +1 (216) 444-2038; fax: +1 (216) 445-3297.

E-mail address: petterg{at}ccf.org (G.B. Pettersson).


    Abstract
 Top
 Abstract
 1. Introduction
 2. Scenario
 3. Discussion
 4. Conclusions
 References
 
Pseudoaneurysms of the ascending aorta developing after previous aortic or aortic valve surgery pose a high risk of exsanguination upon sternal reentry. In the past, femorofemoral bypass and hypothermic circulatory arrest before sternotomy was the preferred approach. Today, however, availability of the PORT-ACCESS EndoCPB system (Edwards Lifesciences, Irvine, CA, USA) allows for endovascular clamping and cardioplegia before sternotomy, avoiding circulatory arrest.

Key Words: Aorta; Aortic valve; Aortic root; Aneurysm; Reoperation


    1. Introduction
 Top
 Abstract
 1. Introduction
 2. Scenario
 3. Discussion
 4. Conclusions
 References
 
The main challenge of managing aortic pseudoaneurysms is sternal reentry, where the risk of exsanguination and air embolization is high using standard techniques. Currently, femorofemoral bypass and hypothermic circulatory arrest before sternotomy is most frequently used [1, 2]. However, arrest time required for sternal reentry, dissection, and controlling the aorta is unpredictable, and even more so after multiple operations. To address this, we present a strategy of cannulation and cardioplegia that can eliminate the need for circulatory arrest during reentry.


    2. Scenario
 Top
 Abstract
 1. Introduction
 2. Scenario
 3. Discussion
 4. Conclusions
 References
 
A 48-year-old male was referred 10 months after a Bentall procedure. His medical history was significant for bicuspid aortic valve, for which he underwent valvuloplasty at the age of 8 years. At age 45, he underwent aortic valve replacement with a mechanical valve and supracoronary ascending aorta replacement with a Hemashield graft. Two years later, he developed prosthetic valve endocarditis and underwent debridement of the aortic root and left ventricular outflow tract, root reconstruction with Peri-Guard, and replacement of the root and ascending aorta using a St Jude mechanical prosthesis extended with a Vascutek graft. He presented with progressive dyspnea. Echocardiography demonstrated dehiscence of the aortic valve prosthesis, pseudoaneurysm around the root and ascending aorta with systolic compression of the graft, and turbulent flow around the left coronary button into the pseudoaneurysm, creating suspicion of a possible second source leak. Computed tomography confirmed the pseudoaneurysm around the graft. The upper 4 cm of the pseudoaneurysm was lying in immediate contact with the sternum (Fig. 1). Additional findings noted included an ejection fraction of 30%, moderately decreased right ventricular function, mild pulmonary hypertension, and moderate mitral and tricuspid regurgitation. Standard reentry into the chest without catastrophic rupture was deemed impossible. Hence, our choice of the PORT-ACCESS EndoCPB system (Edwards Lifesciences, Irvine, CA, USA).


Figure 1
View larger version (30K):
[in this window]
[in a new window]

 
Fig. 1. Computed tomography scan of aortic pseudoaneurysm lying directly beneath the sternum. Note that pseudoaneurysm extends into aortic root, and graft is almost completely compressed (left). Transesophageal echocardiogram shows mechanical valve with color flow into pseudoaneurysm (right).

 
After anesthesia induction and placement of right- and left-sided arterial lines, an EndoPlege coronary sinus catheter was inserted through the right internal jugular vein under transesophageal echocardiogram guidance. The right axillary artery and right femoral vessels were exposed. The lower half of the sternum was opened to define the pericardial plane of dissection and expose the right atrium. The patient was heparinized and right axillary artery, right femoral artery, and right atrium cannulated. An EndoClamp occlusion balloon was inserted through the right femoral artery and positioned in the aorta directly above the aortic prosthesis. Cardiopulmonary bypass was initiated and systemic cooling commenced. At 30 °C, with the heart still beating, the EndoClamp was inflated and heart arrested with retrograde cardioplegia. The sternotomy was completed. Upon opening, it was confirmed that the posterior aspect of the sternum formed the anterior wall of the pseudoaneurysm. The operating field was completely dry in spite of the pseudonaneurysm being open (Fig. 2). The dissection was then completed, a standard aortic clamp placed and the EndoClamp removed. A superior vena cava cannula and standard retrograde catheter were added. By this time, the patients temperature was 20 °C and a brief circulatory arrest period was employed for replacing the distal ascending aorta. The composite graft and Peri-Guard were removed, the anulus debrided, and coronary buttons mobilized. Mitral valve repair was performed with an anuloplasty band. The aortic root was reconstructed with an aortic allograft. Finally, tricuspid valve was repaired with a lateral anulus plication. Total clamp time was 2 h 48 min and circulatory arrest time was 12 min.


Figure 2
View larger version (66K):
[in this window]
[in a new window]

 
Fig. 2. Intraoperative image showing cavity of pseudoaneurysm directly over compressed graft (a) and schematic diagram describing cannulation strategy (b). Notice bloodless field with systemic circulation and heart arrested. Placement of arterial and venous cannulas and PORT-ACCESS EndoCPB EndoClamp and EndoPlege catheters are shown, as well as inflated balloon within compressed graft.

 
Postoperative bleeding was minimal, and the patient was extubated the morning after. He was discharged after six days. All cultures were negative, but he was given a 6-week course of intravenous antibiotics.


    3. Discussion
 Top
 Abstract
 1. Introduction
 2. Scenario
 3. Discussion
 4. Conclusions
 References
 
The most frequent strategy used for aortic pseudoaneurysms involves femoral cannulation and systemic cooling followed by chest entry during circulatory arrest [2]. This strategy is usually successful; however, there is high variability in circulatory arrest time that depends on the density of adhesions, size of pseudoaneurysm, size of leak, and time required to control the aorta. Strategies to decrease circulatory arrest time, such as direct Foley catheter placement through the sternotomy to tamponade bleeding, have had limited success [1].

Our present strategy addresses these issues and represents further refinements in technique [3–5]. There are five keys to this strategy. First, use of both right axillary and femoral arterial cannulation. Because the EndoClamp can occasionally migrate and occlude the innominate artery, cannulating both axillary and femoral arteries ensures adequate cerebral circulation. Additionally, an axillary cannulation allows for antegrade cerebral perfusion if extended circulatory arrest is required. Second, the EndoClamp has cardioplegia and venting ports. Once the balloon of the EndoClamp is inflated, the presence or absence of a distal leak can be surmised by the ability to decompress the heart. In the presence of a distal leak, the heart will not decompress because of continued flow through the pseudonaeurysm and into the heart; and adequate systemic perfusion will not be maintained. This would indicate the need for repositioning of the endoballoon in the proximal arch, system cooling and deep hypothermic circulatory arrest with the option of antegrade cerebral perfusion. Third, EndoPlege allows for delivery of retrograde cardioplegia at the onset. Fourth, opening the lower portion of the sternum allows for definition of the pericardial plane of dissection before entering the pseudoaneurysm. Finally, although femoral vein cannulation is adequate, right atrial cannulation through the lower sternotomy allows for more complete drainage. With this strategy, complete control of the aorta, heart, and brain is achieved, circulatory arrest is not required during sternal reentry, and best possible cerebral and myocardial protection is provided.


    4. Conclusions
 Top
 Abstract
 1. Introduction
 2. Scenario
 3. Discussion
 4. Conclusions
 References
 
Using combined peripheral cannulation and PORT-ACCESS is effective in preventing exsanguination from sternal reentry in patients with aortic pseudoaneurysms. This ability to arrest the heart prior to sternal reentry makes this strategy applicable to all other reoperations where a long period of circulatory arrest needs to be avoided, thereby reducing associated risks and increasing potential for improving short- and long-term outcomes. We believe this strategy can be adopted as the standard of care and can be replicated in most hospitals experienced with technology for minimal access surgery.


    References
 Top
 Abstract
 1. Introduction
 2. Scenario
 3. Discussion
 4. Conclusions
 References
 

  1. Apaydin AZ, Posacioglu H, Islamoglu F, Telli A. A practical tool to control bleeding during sternal reentry for pseudoaneurysm of the ascending aorta. Ann Thorac Surg 2003;75:1037–1038.[Abstract/Free Full Text]
  2. Atik FA, Navia JL, Svensson LG, Vega PR, Feng J, Brizzio ME, Gillinov AM, Pettersson BG, Blackstone EH, Lytle BW. Surgical treatment of pseudoaneurysm of the thoracic aorta. J Thorac Cardiovasc Surg 2006;132:379–385.[Abstract/Free Full Text]
  3. D'Attellis N, Diemont FF, Julia PL, Cardon C, Fabiani JN. Management of pseudoaneurysm of the ascending aorta performed under circulatory arrest by Port-Access. Ann Thorac Surg 2001;71:1010–1011.[Abstract/Free Full Text]
  4. Maselli D, Musumeci F. Transaxillary aortic endoclamping for ascending aortic pseudoaneurysm and dissected descending aorta. Ann Thorac Surg 2005;79:e36–e38.[Abstract/Free Full Text]
  5. Pettersson G, Nores M, Gillinov AM. Transfemoral control of ruptured aortic pseudoaneurysm at aortic root reoperation. Ann Thorac Surg 2004;77:311–312.[Abstract/Free Full Text]




This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Karl G. Reyes
Gosta B. Pettersson
Tomislav Mihaljevic
Eric E. Roselli
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Reyes, K. G.
Right arrow Articles by Roselli, E. E.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reyes, K. G.
Right arrow Articles by Roselli, E. E.
Related Collections
Right arrow Cardiac - other
Right arrow Great vessels
Right arrow Valve disease


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS