ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2009;8:157-159. doi:10.1510/icvts.2008.186023
© 2009 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Salvatore Lentini
Roberto Gaeta
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lentini, S.
Right arrow Articles by Gaeta, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lentini, S.
Right arrow Articles by Gaeta, R.
Related Collections
Right arrowRelated Article

Brief communication - Aortic and aneurysmal

Type A aortic dissection involving the carotid arteries: carotid stenting during open aortic arch surgery

Salvatore Lentini*, Fabrizio Tancredi, Filippo Benedetto and Roberto Gaeta

Department of Cardiac and Vascular Surgery, University Hospital, University of Messina, Messina, Italy

Received 10 June 2008; received in revised form 24 September 2008; accepted 26 September 2008

*Corresponding author. UOC Cardiochirurgia, Policlinico G Martino, Università di Messina, Viale Gazzi, 98100 Messina, Italy. Tel: +(39) 090 2217086; fax: +(39) 090 2217086.

E-mail address: salvolentini{at}alice.it (S. Lentini).


    Abstract
 Top
 Abstract
 1. Introduction
 2. Case report
 3. Discussion
 References
 
Aortic dissection involving the arch can be complicated by extension to the supra-aortic branches. Carotid dissection may be symptomatic or asymptomatic at the time of surgery. Dissection or re-dissection of repaired carotid may happen later, with symptoms occurring days after the surgical repair, increasing the morbidity and mortality of those patients. We report a case of a patient with type A aortic dissection involving the aortic arch and extending to the supra-aortic branches. During surgery the dissection was seen extending to the distal carotid arteries with tears in the inner wall. After use of surgical glue as a sealant, seeing the persistent fragility and the presence of spiral form tears in the internal wall of the carotid arteries, intraoperative stenting of the common carotid arteries was performed using two stents to prevent carotid re-dissection and ischemic stroke in the postoperative period. In patients with aortic dissection and extension into the carotid arteries, especially with presence of tears of the inner wall, after use of a glue as a sealant of the two dissected layers, if the repaired artery wall results are still fragile, use of intraoperative carotid stenting may be of help in preventing late re-dissection.

Key Words: Aortic arch; Dissection; Carotid artery disease; Carotid artery dissection, internal


    1. Introduction
 Top
 Abstract
 1. Introduction
 2. Case report
 3. Discussion
 References
 
Carotid dissection is a well-known cause of stroke. Different causes can be recognized: spontaneous or traumatic [1–3], or due to carotid aneurysm [4] or due to aortic dissection involving the aortic arch and extending to the supra-aortic branches [5]. In those patients, carotid dissection may be symptomatic or asymptomatic at the time of surgery. In this situation, during surgery the ascending aorta or also the arch are replaced by a Dacron prosthesis, and the false lumen of the dissection of the supra-aortic vessels is closed using a surgical glue. However, neurological symptoms even if not present at time of surgery, or in the immediate postoperative period, may sometimes appear days after the surgical repair, increasing the morbidity and mortality of those patients. This is usually due to a re-dissection of the carotid arteries. Different authors described neurologic disorders appearing after surgical repair of type A aortic repair [6, 7] and treated successively by carotid stenting, even in cases appearing one month after surgery [8].

We describe the case of a patient with type A aortic dissection extending to the descending aorta and involving the supra-aortic branches, with distal extension to the carotid vessels. In this case, due to the extension of the lesion, stenting of both of the carotid arteries was performed during surgery, in a preventive fashion.


    2. Case report
 Top
 Abstract
 1. Introduction
 2. Case report
 3. Discussion
 References
 
A 50-year-old man was transferred from another Hospital to our Institution with diagnosis of type A aortic dissection. The patient, since five hours previously, complained of chest pain irradiating to the back and shoulders. No neurological symptoms were present. The limbs appeared perfused, but hyposphygmia was present in the left arm. CT-scan demonstrated aortic dissection involving the ascending aorta extending down to the iliac arteries, and involving the supra-aortic vessels too (Fig. 1). ECG was normal, and myocardial specific enzymes were also normal. Diuresis was impaired. The patient was transferred to the operating room for replacement of the ascending aorta, arch and reimplant of supra-aortic vessels. During surgery the supra-aortic vessels were exposed. Both of the carotid arteries appeared dissected far from the aortic arch and with spiral form tears inside. Adhesion of the two layers of the dissected carotid arteries was performed by the use of gelatin-resorcinol-formaldehyde (Cardial Technopole, St Etienne, France) glue as a sealant. However, even after this treatment the repaired vessel's wall resulted in being still quite fragile and with a worrying aspect of the repaired intimal tears. In the aim to give more stability and strength to the repaired carotid walls even far from the surgeon's suture line, and to reduce the risk of late re-dissection: before re-implantation on the new prosthetic aorta, two stents Carotid Endoprosthesis WallstentTM MonorailTM type 7.0 mm/30.0 mm (Boston Scientific, Natick, MA, USA) were inserted inside the common carotid vessels. The insertion of the stents created a wide true lumen closing completely the dissection for a good length far from the suture line with the new aorta prosthesis. Cerebral protection was maintained through selective cannulation of both carotids (DLP Retrograde Coronary Sinus Perfusion Cannula with manual Inflating Cuff, Medtronic Inc, Minneapolis, USA). Cerebral monitoring was performed with near infrared spectroscopy (INVOS cerebral oxymeter, Somanetics Inc, Troy, USA), brain tissue oxygen saturation measured 60–65% continuously during perfusion.


Figure 1
View larger version (105K):
[in this window]
[in a new window]

 
Fig. 1. Preoperative CT-scan.

 
Surgical procedure was concluded in standard fashion with reimplantation of the supra-aortic branches on the new prosthetic aorta. Postoperative control of the stented vessels was performed both in-hospital and in out-patient clinic using Doppler ultrasound scan (Fig. 2); showing good carotid flow and no residual dissection. Postoperative contrast medium imaging was not performed due to chronic renal failure. In the postoperative period the patient did not show neurological disorders, nor at the six-month post-operative follow-up.


Figure 2
View larger version (50K):
[in this window]
[in a new window]

 
Fig. 2. Ultrtrasound Doppler scan of the dissected carotid vessels after intraoperative stenting. (a) Left carotid artery with stent. (b) Normal flow inside the stented left carotid. (c) Stent inside the right carotid, with good flow. (d) Inside.

 

    3. Discussion
 Top
 Abstract
 1. Introduction
 2. Case report
 3. Discussion
 References
 
In aortic dissection extending to the arch, carotid arteries may be involved. Neurological symptoms may be soon present, or sometimes may appear after surgery even if adhesion of the two layers of the dissected vessel was good at time of surgery. This is because a re-dissection of the vessels can appear after surgery, and this may need later stenting treatment to treat this complication [9]. This re-dissection may probably be due to the fragility of the repaired wall where the surgeon has to insert a suture line causing further trauma.

Using a stent inside the dissected vessel gives more stability and strength to the wall even far from the surgeon's suture line, and may prevent further re-dissection and new neurological symptoms.

We think that this technique, used at time of surgery, and therefore, as an ‘open/hybrid technique’, may be useful in cases of aortic dissection involving the supra aortic branches when the repaired carotid wall appears still fragile or with extending tears. Further investigation will be of help to demonstrate the utility of this technique.

3.1. Limit of the report

The authors understand they used this technique in only one case. The question is, if carotid stenting should be used in all cases of aortic dissection extending to the carotid arteries or only in selected cases? We believe that at the moment this treatment should be reserved just to vessels presenting at time of surgery with extending tears in their inside, and that appear with fragile walls after a standard repair. Therefore, it seems appropriate for the moment to use it in extreme cases. This, also in consideration of the associated risks of stenting as stenosis in their inside or in their edges.

In conclusion, this technique was useful in the case we presented. However, we aim to perform a series to give more information to the scientific community.


    References
 Top
 Abstract
 1. Introduction
 2. Case report
 3. Discussion
 References
 

  1. Biggs KL, Chiou AC, Hagino RT, Klucznik RP. Endovascular repair of a spontaneous carotid artery dissection with carotid stent and coils. J Vasc Surg 2004;40:170–173.[CrossRef][Medline]
  2. Zwierzynska E, Bec L, Sklinda K, Walecki J, Garlicki M, Pniewski J. Common carotid artery dissection in the course of acute aortic dissection De Bakey type I. Neurol Neurochir Pol 2007;41:472–476.[Medline]
  3. Biondi A, Katz JM, Vallabh J, Segal AZ, Gobin YP. Progressive symptomatic carotid dissection treated with multiple stents. Stroke 2005;36:e80–e82.[Abstract/Free Full Text]
  4. Cohen JE, Gomori JM, Grigoriadis S, Elazary R, Almogy G, Zamir G, Rivkind AY, Khalaileh A. Intra-arterial thrombolysis and stent placement for traumatic carotid dissection with subsequent stroke: a combined, simultaneous endovascular approach. J Neurol Sci 2008;17(PMID: 18206911.
  5. Castellan L, Casasco A, Toso V, Bernardi L. Stenting of the extracranial internal carotid artery for dissecting aneurysm. Ital J Neurol Sci 1999;20:251–253.[CrossRef][Medline]
  6. Kawarabuki K, Sakakibara T, Hirai M, Shirasu M, Kohara I, Tanaka H, Oyamada M, Takamatsu T, Murayama Y, Yamaki T. Acute aortic dissection presenting as a neurologic disorder. J Stroke Cerebrovasc Dis 2006;15:26–29.[CrossRef][Medline]
  7. Roseborough GS, Murphy KP, Barker PB, Sussman M. Correction of symptomatic cerebral malperfusion due to acute type I aortic dissection by transcarotid stenting of the innominate and carotid arteries. J Vasc Surg 2006;44:1091–1096.[CrossRef][Medline]
  8. Cardaioli P, Rigatelli G, Giordan M, Faggian G, Chinaglia M, Roncon L. Multiple carotid stenting for extended thoracic aorta dissection after initial aortic surgical repair. Cardiovasc Revasc Med 2007;8:213–215.[CrossRef][Medline]
  9. Pavkov I, Horner S, Klein GE, Niederkorn K. Percutaneous transluminal angioplasty with stenting in extended supra-aortic artery dissection. Croat Med J 2004;45:217–219.[Medline]

Related Article

eComment: Everyday clinical practice consequences?
Patrick Ruchat
Interactive CardioVascular and Thoracic Surgery 2009 8: 159. [Full Text] [PDF]



This article has been cited by other articles:


Home page
ICVTSHome page
P. Ruchat
eComment: Everyday clinical practice consequences?
Interactive CardioVascular and Thoracic Surgery, January 1, 2009; 8(1): 159 - 159.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Salvatore Lentini
Roberto Gaeta
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lentini, S.
Right arrow Articles by Gaeta, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lentini, S.
Right arrow Articles by Gaeta, R.
Related Collections
Right arrowRelated Article


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS