ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2008;7:441-443. doi:10.1510/icvts.2007.168872
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
José Honório Palma
Diego Felipe Gaia
Enio Buffolo
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Palma, J. H.
Right arrow Articles by Buffolo, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Palma, J. H.
Right arrow Articles by Buffolo, E.

Negative results - Aortic and aneurysmal

Early complication after hybrid thoracic aortic aneurysm repair

José Honório Palma, José Stocco Guilhen, Diego Felipe Gaia* and Enio Buffolo

Federal University of São Paulo, Paulista School of Medicine, São Paulo, Brazil

Received 24 September 2007; received in revised form 5 February 2008; accepted 6 February 2008

*Corresponding author. Napoleão de Barros 715, 3° Andar, Cardiovascular Surgery Department, Vila Clementino, São Paulo, S.P., 04038-000, Brazil. Tel.: +(55)(11) 5576-4055; fax: +(55)(11) 5571-2719.

E-mail address: drgaia{at}uol.com.br (D.F. Gaia).


    Abstract
 Top
 Abstract
 1. Background
 2. Case report
 3. Discussion
 References
 
This brief report describes an unusual hybrid approach complication of aortic arch disease. An acute stent kinking in the first post-operative day promoted ventricular fibrillation and death. Adequate oversizing was achieved and intraoperative angiogram showed no proximal or distal leaks. Unfavorable outcomes are highly under-reported and describing complications are a key instrument to improve this technique.

Key Words: Endovascular; Aortic aneurysm; Stent-graft; Hybrid


    1. Background
 Top
 Abstract
 1. Background
 2. Case report
 3. Discussion
 References
 
Standard surgical treatment of aortic dissection and true aneurysm demands thoracotomy, cardiopulmonary bypass (CPB), deep hypothermia and a graft interposition. The recent introduction of endovascular approach may avoid these important risk factors, performing the procedure in a minimally invasive fashion. Besides that, some portions of the aorta, like the arch, are not suitable for standard endovascular approach due to arch branch origin. In such cases, reports suggest hybrid procedures in order to reduce surgical trauma, morbidity and mortality [1, 2].

Surgical and postoperative factors play a role in providing possible superior results when compared to standard intervention in selected cases; reduced blood loss, avoidance of CPB and cross clamp, lower renal failure incidence, lower stroke risk and hospital stay. Conventional and endovascular approaches are under investigation in many centers. EVAR and DREAM trials present some tendency in reducing procedure-related mortality, even in low-risk individuals, with the use of endovascular intervention [3, 4].

In this scenario, the alternative approach using standard and endovascular techniques are becoming a safe strategy in correctly selected patients, and able to promote significant death and complication reduction [3, 4]. Besides that, a new technique may create new complications, many potentially lethal [5]. A case of an unusual complication is described.

The following case report describes one of these new complications.


    2. Case report
 Top
 Abstract
 1. Background
 2. Case report
 3. Discussion
 References
 
A 50-year-old male patient with hypertension, diabetes mellitus and hyperuricemia. The patient was admitted to the emergency unit with oppressive chest pain, with exertion being worst and with no spreading. The pain commenced two years previously and became worse in the last three months, associated with dyspnea, dizziness and both inferior limb paresthesia due to diabetes vascular microangiopathy. Three months ago he had a transient ischemic attack. Actual prescription: angiotensin converting enzyme, B-blocker, calcium channel antagonist, statin and acetylsalicylic acid.

Transesophageal echocardiography (TEE): severe atherosclerotic disease (atheroma >3 mm with mobile and ulcerated plaques), atherosclerotic ulcer (aortic arch), presence of intramural hematoma and pseudo-aneurysm at the left carotid artery. Carotid ultrasonographic examination: severe bilateral common proximal obstruction (70%) with the presence of poor collaterals. Computer tomography: aortic arch ectasia (38 mm), intimal irregularities (arch and descending) with diffuse ulcers (Fig. 1). Coronary angiogram showed no significant lesions.


Figure 1
View larger version (98K):
[in this window]
[in a new window]

 
Fig. 1. Computer tomography. Aortic arch. Penetrating ulcers.

 
The patient underwent a hybrid approach. In the operating room equipped with an angiographic C-arm system and TEE, a midline sternotomy was performed. Without CPB support, an extra-anatomical shunt was fashioned with a Dacron prosthesis linking the ascending aorta to both carotid arteries, using end-to-side anastomosis. Following this, proximal ligations of the carotid arteries were performed in order to avoid cerebral emboli during stent placement. In the same surgical procedure, a self-expandable nitinol stent-graft (Braile Biomedical) was correctly deployed in the aortic arch through the ascending aorta with radioscopic and TEE guidance occluding the brachicephalic artery, left carotid and left subclavian arteries with a previously described technique [1]. A 20% oversize was used. Adequate proximal and distal landing zones were achieved; a final angiogram showed no leaks and correct placement.

On the first postoperative day, the patient presented acute stent kinking and distal migration leading to ventricular fibrillation and death (Fig. 2).


Figure 2
View larger version (58K):
[in this window]
[in a new window]

 
Fig. 2. (a) Chest RX. Kinked stent-graft (arrow). (b) Illustrative scheme.

 

    3. Discussion
 Top
 Abstract
 1. Background
 2. Case report
 3. Discussion
 References
 
The development of hybrid procedures allowed many patients that were considered not suitable for surgical procedure due to high operative risk to be treated, and have been shown to be feasible [6]. Avoidance of CPB and deep hypothermic circulatory arrest (DHCA) seems to be the main benefit. Besides that, a new technique brings different complications, not previously reported.

Byrne et al. [5] reported a recent series with 143 patients treated with hybrid approach, with a mortality rate of 0.7% and a low non-fatal complication rate, including 3 (2.1%) for bleeding, 1 (0.7%) wound infection, 2 (1.4%) transient ischemic atack, 1 (0.7%) non-fatal stroke, 2 (1.4%) postoperative myocardial infarction, and 6 (4.3%) late (>30-day) occlusions. Atrial fibrillation, paraplegia, thromboembolism, retroperitoneal hematoma and displacement of the prosthesis were also reported [5].

This expresses the urgent need to improve the technique and how to treat those patients in the postoperative period. Abdominal aortic aneurysm series, imply these results to poor prosthesis design [7]. These findings could be possibly extrapolated to thoracic aneurysms. In this way, factors related to patient selection and the technique itself is being implicated. Accurate definition of these factors is not well established. Patient related factors, like age, ASA score and pre-operative prescription can predict outcome and hospital stay [8].

Szeto et al. [6] performed this operation under CPB but avoiding DHCA with a decrease in morbidity and mortality associated with conventional repair, with CPB and DHCA an obvious benefit. But a step further, the avoidance of CPB seems to bring even more benefit, even in terms of stroke. Besides the hybrid approach not being completely unharmful, the hospital mortality associated with conventional strategy using CPB and DHCA ranges up to 20%, with a stroke rate up to 12% [9], justifying the investment in this technique.

This report describes a lethal complication due to prosthesis kinking in the early postoperative period. After migration and kinking the prosthesis probably leads to an acute increase in afterload, ventricular distention and irreversible fibrillation. Besides an initial correct deployment, satisfactory proximal and distal landing zones and 20% oversize, the most probable cause was inadequate stent selection. Aortic diameter may vary up to 13.3% during cardiac cycle [10] and computed tomography images used to measure and select the prosthesis diameter could be obtained in an inadequate moment leading to wrong selection. Perhaps dynamic images should be used to measure aortic diameter and select the adequate stent oversize in order to avoid such a complication.

Endovascular and hybrid approach are becoming a new alternative in the treatment of aortic diseases, especially in patients with prohibitive risk to standard procedure. Improved results are still under investigation and ideal candidates are not well defined. Like others, this approach is not free of important complications, even requiring urgent conventional rescue procedures and special techniques.

Unfortunately, there is a slight tendency not to publish unfavorable outcomes and a lot of problems and pitfalls remain hidden. Reporting adverse results is an obligation of groups performing endovascular procedures. This position will certainly promote new knowledge and solutions in order to improve these emerging therapy results.


    References
 Top
 Abstract
 1. Background
 2. Case report
 3. Discussion
 References
 

  1. Palma JH, de Souza JA, Rodrigues Alves CM, Carvalho AC, Buffolo E. Self-expandable aortic stent-grafts for treatment of descending aortic dissections. Ann Thorac Surg 2002;73:1138–1141.[Abstract/Free Full Text]
  2. Parodi JC. Endovascular repair of abdominal aortic aneurysms and other arterial lesions. J Vasc Surg 1995;21:549–555.[CrossRef][Medline]
  3. Endovascular aneurysm repair and outcome in patients unfit for open repair of abdominal aortic aneurysm (EVAR trial 2): randomised controlled trial. Lancet 2005;365:2187–2192.[CrossRef][Medline]
  4. Blankensteijn JD, de Jong SE, Prinssen M, van der Ham AC, Buth J, van Sterkenburg SM, Verhagen HJ, Buskens E, Grobbee DE. Two-year outcomes after conventional or endovascular repair of abdominal aortic aneurysms. N Engl J Med 2005;352:2398–2405.[Abstract/Free Full Text]
  5. Byrne J, Darling RC III, Roddy SP, Mehta M, Paty PS, Kreienberg PB, Chang BB, Ozsvath KJ, Sternbach Y, Shah DM. Long-term outcome for extra-anatomic arch reconstruction. An analysis of 143 procedures. Eur J Vasc Endovasc Surg 2007;34:444–450.[CrossRef][Medline]
  6. Szeto WY, Bavaria JE, Bowen FW, Woo EY, Fairman RM, Pochettino A. The hybrid total arch repair: brachiocephalic bypass and concomitant endovascular aortic arch stent graft placement. J Card Surg 2007;22:97–102.[CrossRef][Medline]
  7. Riambau V, Laheij RJ, Garcia-Madrid C, Sanchez-Espin G. The association between co-morbidity and mortality after abdominal aortic aneurysm endografting in patients ineligible for elective open surgery. Eur J Vasc Endovasc Surg 2001;22:265–270.[CrossRef][Medline]
  8. Conners MS III, Tonnessen BH, Sternbergh WC III, Carter G, Yoselevitz M, Money SR. Does ASA classification impact success rates of endovascular aneurysm repairs? Ann Vasc Surg 2002;16:550–555.[CrossRef][Medline]
  9. Svensson LG, Crawford ES, Hess KR, Coselli JS, Raskin S, Shenaq SA, Safi HJ. Deep hypothermia with circulatory arrest. Determinants of stroke and early mortality in 656 patients. J Thorac Cardiovasc Surg 1993;106:19–28.[Abstract]
  10. Herwaarden JA, Bartels LW, Muhs BE, Vincken KL, Lindeboom MYA, Teutelink A, Moll FL, Verhagen HJ. Dynamic magnetic resonance angiography of the aneurysm neck: conformational changes during the cardiac cycle with possible consequences for endograft sizing and future design. J Vasc Surg 2006;44:22–28.[CrossRef][Medline]




This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
José Honório Palma
Diego Felipe Gaia
Enio Buffolo
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Palma, J. H.
Right arrow Articles by Buffolo, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Palma, J. H.
Right arrow Articles by Buffolo, E.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS