ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on November 30, 2009, doi:10.1510/icvts.2009.221036

Interactive CardioVascular and Thoracic Surgery 2010;10:325.

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Kewal Krishan
Sean Pinney
Anelechi C. Anyanwu
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Krishan, K.
Right arrow Articles by Anyanwu, A. C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krishan, K.
Right arrow Articles by Anyanwu, A. C.
Related Collections
Right arrow Congestive Heart Failure
Right arrow Mechanical Circulatory Assistance
Right arrow Valve disease

Assisted circulation

Successful use of continuous flow ventricular assist device in patient with mechanical mitral and aortic valve prosthesis without replacement or exclusion of valves

Kewal Krishan 1, Sean Pinney 1, Anelechi C. Anyanwu 1*

1 Mount Sinai Medical Center, New York, USA

* To whom correspondence should be addressed. E-mail: anianyanwu{at}hotmail.com.


   Abstract
In patients with left-sided mechanical aortic prostheses, it is recommended that the mechanical valve be replaced with a bioprosthesis, or excluded, at implantation of left ventricular assist device (LVAD). As changes in flow across the valve leads to potential thromboembolic complications, mechanical valves within the native heart are a relative contraindication to LVAD therapy. We here describe a patient who had long-standing valvular cardiomyopathy with mitral Starr-Edwards mechanical valve (Edwards Lifesciences, CA, USA) and aortic bileaflet tilting disc (St.Jude Medical, St Paul, MN, USA) where LVAD was placed without explantation of the mechanical heart valves. The patient was bridged successfully to transplantation without thromboembolic events. Keywords: Ventricular assist device; Mechanical heart valves; Thromboembolism





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2009 European Association for Cardio-thoracic Surgery