ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on June 29, 2009, doi:10.1510/icvts.2009.206706

Interactive CardioVascular and Thoracic Surgery 2009;9:399.

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Nakayama, H.
Right arrow Articles by Tsuboi, M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nakayama, H.
Right arrow Articles by Tsuboi, M.
Related Collections
Right arrow Lung - cancer
Right arrow Mediastinum

Experimental

Ultrasonic scalpel for sealing of the thoracic duct: evaluation of effectiveness in an animal model

Haruhiko Nakayama 1*, Hiroyuki Ito 1, Yasufumi Kato 1, Masahiro Tsuboi 1

1 Kanagawa Cancer Center, Nakao, Asahi-Ku, Yokohama, Japan

* To whom correspondence should be addressed. E-mail: nakayama-h{at}kcch.jp.


   Abstract
To verify the usefulness of an ultrasonic scalpel for the sealing of lymphatic ducts, a Harmonic Ace scalpel (Ethicon Endo-Surgery, Inc, Cincinnati, OH) was tested, using the thoracic ducts in pigs. Indocyanine green was injected into the abdominal lymphatic ducts in two pigs, and the stained thoracic ducts were identified. The thoracic ducts were then divided and sealed into seven sections with a Harmonic Ace scalpel, used at a power setting of level 3. The cut ends of the thoracic ducts were evaluated macroscopically, Histologically, and by measuring bursting pressure. The whole length of thoracic duct of each pig was clearly imaged by pigment. Each stump divided by the ultrasonic scalpel was completely sealed, and there was no pigment leakage from the cut end macroscopically. Histologic examination revealed that the cut end was sealed by homogenous degenerative coagulation. Bursting pressures could be determined at three cut ends of thoracic ducts and were 195 mmHg, 188 mmHg, and 203 mmHg, respectively. The thoracic ducts were reliably divided and sealed by an ultrasonic scalpel in pigs. This device is expected to be a useful tool for the surgical treatment of chylothorax. Keywords: Lung cancer surgery; Ultrasonic scalpel; Thoracic duct; Chylothorax; Postoperative complications; Lymph node dissection





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2009 European Association for Cardio-thoracic Surgery