ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on June 18, 2009, doi:10.1510/icvts.2009.203356

Interactive CardioVascular and Thoracic Surgery 2009;9:391.

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Kouritas, V. K.
Right arrow Articles by Molyvdas, P. A.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kouritas, V. K.
Right arrow Articles by Molyvdas, P. A.
Related Collections
Right arrow Pleura

Experimental

Pleural electrophysiology variations according to location in pleural cavity

Vasileios K. Kouritas 1*, Chrisi Hatzoglou 1, Konstantinos I. Gourgoulianis 1, Paschalis A. Molyvdas 1

1 Larissa University Hospital, Greece

* To whom correspondence should be addressed. E-mail: kouritas{at}otenet.gr.


   Abstract
The aim of the study was to compare the electrophysiology profile of sheep pleura originated from different locations of the pleural cavity with the respective profile in humans. Sheep specimens obtained from upper and lower lung lobes, 1st-4th and 8th-12th rib, ventral-dorsal diaphragm and mediastinum were mounted between Ussing chambers. Human visceral tissues were obtained from patients subjected to lobectomy. Trans-mesothelial resistance (RTM) was determined as an indicator of the tissue permeability, while amiloride and ouabain were used as inhibitors of cellular transportation via ion transporters. Control values RTM were low in lower lobe visceral, caudal costal parietal and diaphragmatic pleura. Amiloride increased RTM at all locations except upper visceral and mediastinum. Higher RTM increases were found in caudal parietal and dorsal diaphragmatic samples. Ouabain increased RTM of lower visceral, caudal parietal and diaphragmatic pleura but not of mediastinal specimens. Observations made in sheep tissue were comparable with human visceral, parietal and mediastinal regions. In conclusion, results suggest heterogeneity of trans-mesothelial permeability among different pleural locations in sheep as was the case for humans. Thoracic surgeons should consider physiology function of each part of pleural cavity before pleural tissue manipulation. Observations made in sheep may be used to understand human physiology. Keywords: Pleura; Sheep; Electrophysiology; Permeability; Ussing





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2009 European Association for Cardio-thoracic Surgery