ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on September 23, 2008
Interactive CardioVascular and Thoracic Surgery 2008, doi:10.1510/icvts.2008.191262
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow eComments: Submit
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Hunt, I.
Right arrow Articles by Bedard, E. L.R.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hunt, I.
Right arrow Articles by Bedard, E. L.R.
Related Collections
Right arrow Pleura

Thoracic general

Establishing a role for intra-pleural fibrinolysis in managing traumatic haemothoraces

Ian Hunt 1*, Chrish Thakar 2, Rachel Southon 3, Eric L.R. Bedard 1

1 University of Alberta, Edmonton, Canada
2 Harefield Hospital, Middlesex, UK
3 Royal Surrey County Hospital, Guildford, UK

* To whom correspondence should be addressed. E-mail: ianjhunt{at}gmail.com.


   Abstract
A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was whether there is a role in using intra-pleural fibrinolysis or thrombolysis with an agent such as streptokinase aids in resolving haemothoraces following trauma. 24 papers were identified using the search below. Eight papers presented the best evidence to answer the clinical question. The author, journal, date and country of publication, patient group studied, study type, relevant outcomes, results, and study weaknesses of the papers are tabulated. We conclude that intra-pleural fibrinolytic does have a role in managing patients with unresolved haemathoraces with complete resolution clinically and radiologically in most patients in half the studies reviewed. It may be used as an alternative to surgical intervention in certain patients, but little work has been done on comparing intra-pleural fibrinolysis directly to surgical evacuation. The choice of agent and number of administrations are variable but with a similar outcome. Few studies have compared agents. The timing of when to use these agents following the traumatic haemothorax was variable but its use was commonly reserved following 'failure' of chest drainage clinically or radiologically (so usually over a week following the original injury). The overall morbidity including bleeding complications from their use was reported as low. Keywords: Evidence-based medicine; Thoracic surgery; Intra-pleural fibrinolysis; Intra-pleural thrombolysis; Intra-pleural streptokinase; Haemothorax





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 European Association for Cardio-thoracic Surgery