ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on September 23, 2008
Interactive CardioVascular and Thoracic Surgery 2008, doi:10.1510/icvts.2008.189332
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow On-line video
Right arrow eComments: View
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Okamoto, Y.
Right arrow Articles by Shimura, K.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Okamoto, Y.
Right arrow Articles by Shimura, K.
Related Collections
Right arrow Valve disease

Valves

Aortic valve papillary fibroelastoma that developed rapidly after open-heart surgery

Yuki Okamoto 1*, Masahiko Matsumoto 1, Hidenori Inoue 1, Kisyo Shimura 1

1 Yamanashi University, Japan

* To whom correspondence should be addressed. E-mail: yamanashimedical{at}yahoo.co.jp.


   Abstract
The patient was a 76-year-old woman who underwent left atrial thrombectomy in November 2003 at our hospital. A mass adhered to the non-coronary aortic cusp was found during annual echocardiography, and the patient was admitted to our hospital. Transthoracic echocardiography detected 2 masses with pendulum-like movement: a 7-mm mass adhered to the non-coronary cusp and a 5-mm mass on the right coronary cusp. Papillary fibroelastoma was diagnosed based on the absence of inflammatory reactions or valvular destruction. Anticoagulant therapy was continued to prevent left atrial thrombus formation. At surgery, a 7-mm mass was adhered to the belly of the non-coronary cusp and a 5-mm pediculate mass was attached to a site near the nodule of Arantius of the right coronary cusp. Movable fibrous connective tissue 4 mm in length was present at 2 sites near the nodule of Arantius of the left coronary cusp, and these were also excised. All excised specimens, including those considered to be connective tissue, were found to be papillary fibroelastoma on pathological examination. Four papillary fibroelastomas that developed in all the cusps, including two small connective tissue-like morphologies and two sea anemone-like morphologies, indicated the process of papillary fibroelastoma growth and looked like 'a family'. Keywords: Valve disease; Papillary fibroelastoma; Cardiac tumor


eComments:

Read all eComments

eComment. Did the papillary fibroelastoma really grow rapidly?
Karthik R. Vaidyanathan
ICVTS Online, 9 Oct 2008 [Full text]
eResponse. Did the papillary fibroelastoma really grow rapidly?
Yuki Okamoto, et al.
ICVTS Online, 15 Oct 2008 [Full text]