ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on August 19, 2008
Interactive CardioVascular and Thoracic Surgery 2008, doi:10.1510/icvts.2008.184457
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Bochenek-Klimczyk, K.
Right arrow Articles by Sosnowski, A.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bochenek-Klimczyk, K.
Right arrow Articles by Sosnowski, A.
Related Collections
Right arrow Cardiac - other
Right arrow Great vessels

Vascular thoracic

Preassembled stentless valved-conduit for the replacement of the ascending aorta and aortic root

Krystyna Bochenek-Klimczyk 1, Kelvin K.W. Lau 1, Manuel Galinanes 1*, Andrzej Sosnowski 1

1 Glenfield Hospital, Leicester, UK

* To whom correspondence should be addressed. E-mail: mg50{at}le.ac.uk.


   Abstract
Here we report the early clinical results of a new preassembled stentless valved-conduit incorporating artificial sinuses of Valsalva (BioValsalvaTM). This new composite conduit incorporates a stentless porcine aortic valve (Elan, Vascutek Terumo, UK) suspended within a triple-layered vascular conduit (TriplexTM, Vascutek Terumo, UK) constructed with sinuses of Valsalva. Between December 2006 and January 2008, 17 patients with the mean age of 65 years underwent aortic valve, root and ascending aorta replacement with the BioValsalvaTM valved-conduit. There was no perioperative mortality. There were no myocardial infarctions, cardiac failure or cerebrovascular events. Mean cardiopulmonary bypass time was 156±56 min and ischemic time was 112±33 min. Eight patients required deep hypothermic circulatory arrest for additional distal ascending aorta replacement. Mean mediastinal drainage was 499±262 ml. Postoperative transthoracic echocardiography and CT scans of the aorta in all patients before discharge demonstrated well-functioning prosthetic aortic valves with small residual mean gradients, no regurgitation, and the presence of sinuses of Valsalva. In conclusion, the novel prefabricated, composite stentless-valved conduit BioValsalvaTM possesses excellent hemodynamic performance and can be implanted with low morbidity. In addition, the conduit material has good hemostatic properties which reduced bleeding, and is easy to implant with a variety of surgical techniques. Keywords: Aortic valve replacement; Aortic root; Aortic operation; Valve disease





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 European Association for Cardio-thoracic Surgery