ICVTS Click here to locate an Ethicon representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on June 9, 2008
Interactive CardioVascular and Thoracic Surgery 2008, doi:10.1510/icvts.2008.180497
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow eComments: View
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Healy, D. G.
Right arrow Articles by Aherne, T.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Healy, D. G.
Right arrow Articles by Aherne, T.
Related Collections
Right arrow Cardiac - physiology
Right arrow Cardiac - other
Right arrow Coronary disease
Right arrow Electrophysiology - arrhythmias

Cardiac general

Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post cardiotomy patient

David G. Healy 1*, Martin Hargrove 1, Kishore Doddakulla 1, John Hinchion 1, Aongus O'Donnell 1, Thomas Aherne 1

1 Cork University Hospital, Wilton, Cork, Ireland

* To whom correspondence should be addressed. E-mail: cardiothoracic{at}gmail.com.


   Abstract
We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and in addition to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better then VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow DDD pacing again had the highest flow [DDD-univentricular 55 ml/min (24), DDD-biventricular 52 ml/min (25), VVI-univentricular 47 ml/min (23), VVI-biventricular 50 ml/min (26)]. DDD-univentricular pacing was significantly better then VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output. Keywords: Pacing; Biventricular; Cardiac output; Coronary conduit flow; DDD; VVI


eComments:

Read all eComments

eComment. Biventricular pacing in cardiac surgery – potential role for non-invasive cardiac output monitoring and nt-pro-BNP determination
Karsten Knobloch
ICVTS Online, 20 Jun 2008 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 European Association for Cardio-thoracic Surgery