ICVTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on April 16, 2008
Interactive CardioVascular and Thoracic Surgery 2008, doi:10.1510/icvts.2008.175000
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow On-line Video
Right arrow eComments: Submit
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Numan, F.
Right arrow Articles by Cikirikcioglu, M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Numan, F.
Right arrow Articles by Cikirikcioglu, M.
Related Collections
Right arrow Cerebral protection
Right arrow Extracorporeal circulation
Right arrow Great vessels
Right arrow Minimally invasive surgery

Experimental

Total endovascular aortic arch reconstruction via fenestration in situ with cerebral circulatory support: an acute experimental study

Furuzan Numan 1, Harun Arbatli 2*, Walter Bruszewski 3, Mustafa Cikirikcioglu 4

1 Cerrahpasa Medical Faculty, Istanbul University, Turkey
2 Memorial Hospital, Istanbul, Turkey
3 Endovascular Innovations, Medtronic CardioVascular, Santa Rosa, CA, USA
4 University Hospital of Geneva, Switzerland

* To whom correspondence should be addressed. E-mail: harbatli{at}yahoo.com.


   Abstract
The aim of this experimental study is to evaluate the feasibility of endovascular repair of the complete aortic arch by using novel fenestration devices with simultaneous support of the cerebral circulation. Two fresh human cadavers and five Yorkshire pigs were used for the experiments. In human cadavers the thoracic aorta was pressurized using a roller pump to simulate the circulation. In animal experiments right femoral artery to right distal carotid artery bypass circuit was achieved in order to support the cerebral circulation during the stent graft deployment, fenestration and conduit fixation procedures. Commercially available Valiant Thoracic Stent Grafts, covered stents, steerable guiding catheters and dilatation balloons were used. Stent grafts were deployed successfully and two fenestrations and one conduit implantation were achieved in each cadaver. All animals survived the stent graft implantation, fenestration and conduit implantation procedures. Cadaver dissection and necropsy of the animals revealed good fixation of the conduits into the fenestrated segments of the stent graft. Endovascular repair of the total aortic arch via in situ fenestration of the stent graft using cerebral circulatory support seems to be feasible and safe. Further studies are required before clinical adoption of this procedure. Keywords: Aortic arch aneurysm; Endovascular stent graft; Cerebrovascular circulation