ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2009;8:206-210. doi:10.1510/icvts.2008.187666
© 2009 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Toshihiko Shibata
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shibata, T.
Right arrow Articles by Mizoguchi, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shibata, T.
Right arrow Articles by Mizoguchi, H.

Institutional report - Valves

Which valve and which size should we use in the valve-on-valve technique for re-do mitral valve surgery?

Toshihiko Shibataa,*, Kazushige Inoueb, Takeshi Ikutab, Yasuyuki Bitob, Yoshiteru Yoshiokab and Hiroki Mizoguchib

a Department of Cardiovascular Surgery, Osaka City General Hospital, 2-13-22, Miyakojima-hondori, Miyakojima, Osaka, 534-0021, Japan
b Department of Cardiovascular Surgery, Kansai Rosai Hospital, Amagasaki, Japan

*Corresponding author. Tel.: +81-6-6929-1221; fax: +81-6-6929-1090.

E-mail address: shibata-cvs{at}zeus.eonet.ne.jp (T. Shibata).

The valve-on-valve (VOV) technique is that a mechanical valve is implanted on the sewing cuff of the previous bioprosthesis after removing degenerated leaflets. We conducted an in vitro study to determine the size-match of the valves for VOV technique. The Carpentier–Edwards pericardial (CEP) valve and Mosaic valve were used. We measured the inner diameter of the bioprosthesis after removing the leaflets. We investigated five mechanical mitral valves and two mechanical aortic valves (inverted use). The mitral valves used in this study were the ATS valve (ATS), the CarboMedics standard valve (CMS), the CarboMedics OptiForm valve (CMO), the On-X valve, and the St Jude valve (SJM). Two aortic mechanical valves, CarboMedics and St Jude Regent valves, were investigated for inverted use. After removing the tissue leaflets, the inner diameter of the Mosaic valve was 3 mm smaller than that of the CEP valve even in the same catalogue labeling size. The outer diameters of the housing of the ATS, CMS, CMO, On-X, and SJM valves of the same catalogue size (25 mm) were 25.7, 25.8, 22.0, 25.0, and 23.2 mm, respectively. SJM and CMO valves are the favorite mechanical valve for the VOV technique in terms of the profile and size-match.

Key Words: Valve-on-valve; Mitral valve replacement; Re-do; Bioprosthesis







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2009 European Association for Cardio-thoracic Surgery