ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2009;8:179-181. doi:10.1510/icvts.2008.184200
© 2009 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Giovanni Ruvolo
Khalil Fattouch
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ruvolo, G.
Right arrow Articles by Fattouch, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ruvolo, G.
Right arrow Articles by Fattouch, K.

New ideas - Aortic and aneurysmal

Aortic valve-sparing root replacement from inside the aorta using three Dacron skirts preserving the native Valsalva sinuses geometry and stabilizing the annulus

Giovanni Ruvolo and Khalil Fattouch*

Department of Cardiac Surgery, University of Palermo, Via Liborio Giuffré, 5, 90127, Palermo, Italy

*Corresponding author. Tel.: +39 091 6554713; fax: +39 091 6554710.

E-mail address: khalilfattouch{at}hotmail.com (K. Fattouch).

We present an alternative idea for valve-sparing technique combining the advantages of the reimplantation and the benefits of the remodeling techniques. We replace the sinuses of Valsalva using three Dacron skirts from inside of the aorta. The physiological anatomy of the Valsalva sinuses and their dynamic properties are preserved and the aortic commissures displacement avoided. The distal rim of each Dacron skirt was anchored to the aorto-ventricular junction using Ticron (2-0) U stitches placed from the ventricular side to the aortic side. We stabilize the base of the aortic annulus to prevent future dilation.

Key Words: Aortic root aneurysm; Valve-sparing surgery; Easy procedure




This article has been cited by other articles:


Home page
ICVTSHome page
S. Perrotta and S. Lentini
Ministernotomy approach for surgery of the aortic root and ascending aorta
Interactive CardioVascular and Thoracic Surgery, November 1, 2009; 9(5): 849 - 858.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2009 European Association for Cardio-thoracic Surgery