ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2009;8:114-116. doi:10.1510/icvts.2008.184135
© 2009 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Shang Dong Xu
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Xu, S. D.
Right arrow Articles by Huang, F. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Xu, S. D.
Right arrow Articles by Huang, F. J.

Negative results - Vascular thoracic

Complications of open stent-graft in treatment of aortic dissection

Shang Dong Xua,*, Bao Zhong Yangb, Zhan Ming Fanc and Fang Jiong Huanga

a Division of Cardiac Surgery, Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Vascular Diseases, Capital Medical University, Beijing, China
b Division of Vascular Surgery, Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Vascular Diseases, Capital Medical University, Beijing, China
c Division of Radiology, Beijing Anzhen Hospital, Beijing Institute of Heart, Lung and Vascular Diseases, Capital Medical University, Beijing, China

*Corresponding author. Fax: +86-010-64456576.

E-mail address: xushangdong{at}vip.sina.com (S.D. Xu).

Open stent-graft has been used in the treatment of aortic dissection in recent years. Two device related complications happened in two patients. One was stenosis of the true lumen in the descending aorta caused by infolding of the distal end of the stent-graft immediately after its deployment. The other one was a new intima tear at the distal end of the stent-graft caused by full expansion of the stent-graft two years after stent-graft implantation. With the refinement of the device and enrichment of surgeons' experience, such complications could be avoided in the future.

Key Words: Aortic dissection; Stent-graft