Interact CardioVasc Thorac Surg 2008;7:925-927. doi:10.1510/icvts.2008.184119 © 2008 European Association of Cardio-Thoracic Surgery
Brief communication - Experimental |
New and simplified method for multiple left ventricle catheterizations in small animals
Francesco Mignecoa,b,*,
Yen-Chih Huangb,
Garrett N. Coyana and
Ravi K. Birlaa
a Section of Cardiac Surgery, The University of Michigan, Ann Arbor, MI 48109, USA
b Department of Biomedical Engineering, The University of Michigan, Ann Arbor, MI 48109, USA
*Corresponding author. 2248 Lurie Biomedical Building, 1101 Beal Ave, Ann Arbor, MI 48109, USA. Tel.: +1 734-615-1481; fax: +1 734-615-2847.
E-mail address: fmigneco{at}umich.edu (F. Migneco).
Ventricular catheterization in the rat is a widely deployed procedure. Current options allow a one-time catheterization procedure, introducing an error due to the inter-individual variability. Six Fischer rats underwent left ventricular catheterization through the right carotid artery, repeated seven days later via the left carotid artery. We acquired volume and pressure data from each animal during both procedures. Volumes and pressures were plotted to construct pressure–volume loops at the two time-points. The neurological outcome and the gross anatomy of the heart were also evaluated. We did not observe any major behavioral or neurological alteration in any of the animals. We observed a Horner syndrome with palpebral ptosis and enophtalmus in one animal. At the macroscopic evaluation of the explanted hearts, we observed perforation of the left ventricle in one case. This is a safe, easy, and reproducible procedure; it can be performed twice in the same animal with no neurological consequences. It is particularly suitable for longitudinal studies, to minimize the statistical error due to inter-individual variability.
Key Words: Rat catheterization; Animal models; In-vivo measurement; Left ventricle catheterization
Related Articles
-
eComment: Left ventricular catheterization for pressure-volume loop measurements in small laboratory animals
- Murat Ugurlucan, Dario Furlani, Christian Klopsch, and Gustav Steinhoff
Interactive CardioVascular and Thoracic Surgery 2008 7: 927.
[Full Text]
[PDF]
-
eResponse: Left ventricular catheterization for pressure-volume loop measurements in small laboratory animals
- Francesco Migneco, Yen-Chih Huang, Garrett N. Coyan, and Ravi K. Birla
Interactive CardioVascular and Thoracic Surgery 2008 7: 927.
[Full Text]
[PDF]
This article has been cited by other articles:

|
 |

|
 |
 
M. Ugurlucan, D. Furlani, C. Klopsch, and G. Steinhoff
eComment: Left ventricular catheterization for pressure-volume loop measurements in small laboratory animals
Interactive CardioVascular and Thoracic Surgery,
October 1, 2008;
7(5):
927 - 927.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Migneco, Y.-C. Huang, G. N. Coyan, and R. K. Birla
eResponse: Left ventricular catheterization for pressure-volume loop measurements in small laboratory animals
Interactive CardioVascular and Thoracic Surgery,
October 1, 2008;
7(5):
927 - 927.
[Full Text]
[PDF]
|
 |
|
|
|