Interact CardioVasc Thorac Surg 2008;7:738-739. doi:10.1510/icvts.2007.172114 © 2008 European Association of Cardio-Thoracic Surgery
Biventricular assist device implantation as bridge to heart transplantation concomitant with open repair of infrarenal aortic aneurysmDepartment of Cardiovascular Surgery, Hôpitaux Universitaires de Strasbourg, 1 Place de l'Hôpital, BP 426, 67091 Strasbourg Cedex, France
*Corresponding author. Tel.: +33 3/88/11/62/44; fax: +33 3/88/11/62/43. Abdominal aortic aneurysm (AAA) is very frequently accompanied by coronary artery disease. Myocardial ischemia is the leading cause of mortality and morbidity in AAA repair. Therapeutic strategy, in presence of ischemic heart failure and AAA, is not well established. Actually, AAA is considered as a contraindication to ventricular assist device (VAD) support. We report a unique case of concomitant open AAA repair and biVAD implantation in a patient with severe ischemic heart failure. This case argues that AAA should no longer be considered a contraindication for VAD implantation, provided the AAA repair is made before or simultaneously with device placement.
Key Words: Aneurysm; Circulatory assist devices; Heart failure; Transplantation, heart; Vascular disease
|