ICVTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2008;7:179-183. doi:10.1510/icvts.2007.167569
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Rosendo A. Rodriguez
Marc Ruel
Thierry Mesana
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Rodriguez, R. A.
Right arrow Articles by Mesana, T.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rodriguez, R. A.
Right arrow Articles by Mesana, T.
Related Collections
Right arrow Cardiac - physiology
Right arrow Cerebral protection
Right arrow Valve disease

Work in progress report - Valves

Transcranial Doppler and acoustic pressure fluctuations for the assessment of cavitation and thromboembolism in patients with mechanical heart valves

Rosendo A. Rodrigueza,*, Marc Ruela, Michel Labrosseb and Thierry Mesanaa

a Department of Surgery, Division of Cardiac Surgery, University of Ottawa Heart Institute, Room H-4403, 40 Ruskin Street, Ottawa, Ontario, K1Y 4W7, Canada
b Department of Mechanical Engineering, Faculty of Engineering, University of Ottawa, Ottawa, Ontario, Canada

*Corresponding author. Tel.: +1-613-761-4263; fax: +1-613-761-4392.

E-mail address: Rrodriguez{at}ottawaheart.ca (R.A. Rodriguez).

The formation and collapse of vapor-filled bubbles near a mechanical heart valve is called cavitation. Such microbubbles are suspected to have strong pro-coagulant effects. Therefore, cavitation may be a contributing factor to the pro-thrombotic effects of mechanical valves. Herein, we systematically review the available evidence linking cavitation and thrombosis. We also critically appraise the potential usefulness of transcranial Doppler and other new non-invasive diagnostic methods to study cavitation and cerebral embolism in mechanical valve patients. Experimental studies indicate that cavitation microbubbles cause platelet aggregation, complement-activation, fibrinolysis, release of tissue-factor, and endothelial damage. Administration of 100% oxygen to mechanical valve patients during transcranial Doppler examination can transiently decrease the counts of Doppler-detected cerebral microemboli compared with room air. This is associated with removal of most circulating gaseous emboli from cavitation. This method may therefore be applied to the study of cavitation and thromboembolism. Additionally, the analysis of high-frequency acoustic-pressure fluctuations detected from the implosion of cavitation bubbles is a promising method for assessment of cavitation in vivo; however, this requires further development. A better understanding of cavitation is important in order to adequately investigate its role in the overall pro-thrombotic effects in mechanical valve patients. Such studies may allow establishing guidelines for new valve designs.

Key Words: Heart valve prosthesis; Thromboembolism; Transcranial Doppler; Air embolism







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 European Association for Cardio-thoracic Surgery