ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2008;7:23-26. doi:10.1510/icvts.2007.168831
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Ernesto Greco
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Urso, S.
Right arrow Articles by Greco, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urso, S.
Right arrow Articles by Greco, E.
Related Collections
Right arrow Cardiac - other

Work in progress report - Cardiac general

Skeletonization of the internal thoracic artery: a randomized comparison of harvesting methods

Stefano Urso*, Luis Alvarez, Rafael Sádaba and Ernesto Greco

Policlinica Gipuzkoa, Cirugía Cardiaca, San Sebastián, Spain

*Corresponding author. Clínica Recoletas, Plaza del Madroño, 11, 02006 Albacete, Spain, Tel.: +34-680560349; fax: +34-967245183.

E-mail address: stefano_urso{at}inwind.it (S. Urso).

We performed a randomized study to compare internal thoracic artery (ITA) flow response to two harvesting methods used in the skeletonization procedure: ultrasonic scalpel and bipolar electrocautery. Sixty patients scheduled for CABG were randomized to receive either ultrasonically (n=30 patients) or electrocautery (n=30 patients) skeletonized ITAs. Intraoperative ITA graft mean flows were obtained with a transit-time flowmeter. ITA flows were evaluated at the beginning (Time 1) and at the end (Time 2) of the harvesting procedure. Post-cardiopulmonary bypass (CPB) flow measurement (Time 3) was obtained in the ITA grafts anastomosed to the left anterior descending artery. Intraoperative mean flow decreased significantly within ultrasonic group (Group U) and electrocautery group (Group E) at the end of the harvesting procedure (P<0.0001 in both cases). Within both groups the final mean flow measured on anastomosed ITAs (Time 3) was significantly higher than the beginning ITA flow value (Time 1). No statistical difference was noted comparing ITA flows between the two groups at any time of evaluation. Skeletonization harvesting of the ITA produces a modification of the mean flow. The quantity and the reversibility of this phenomenon, probably related to vasospasm, are independent from the energy source used in the skeletonization procedure.

Key Words: Internal thoracic artery; Skeletonization; Ultrasound







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 European Association for Cardio-thoracic Surgery