Interact CardioVasc Thorac Surg 2007;6:580-581. doi:10.1510/icvts.2007.158808 © 2007 European Association of Cardio-Thoracic Surgery
Intraoperative saline injection leak test – a simple method to assess mitral valve repair when a simultaneous aortotomy does not allow pressurization of the left ventricle
a Department of Cardiovascular Surgery, Yamanashi Central Hospital, 1-1-1 Fujimi, Kofu, Yamanashi, 400-0027 Japan
*Corresponding author: T el.: +81-55-253-7111; fax: +81-55-253-8011. We describe a simple, safe and reliable intraoperative saline injection leak test for accomplishing and testing the efficacy of mitral valve repair when a simultaneous aortotomy is present.
Key Words: Mitral valve repair; Leak test; Aortotomy