Interact CardioVasc Thorac Surg 2007;6:505-507. doi:10.1510/icvts.2006.149625 © 2007 European Association of Cardio-Thoracic Surgery
Submitral left ventricular pseudoaneurysm after mitral valve replacement: early diagnosis and successful repair
a Department of Cardiology, King Edward VII Memorial Hospital, Mumbai, India
*Corresponding author: C.O. Quarters Building No. 2, Flat 2, King Edward VII Memorial Hospital, Mumbai, India. Late left ventricle (LV) rupture with pseudoaneurysm after mitral valve replacement is rare. We report its early diagnosis by advanced technologies, e.g. MRI and successful repair of a type I AV rupture through left atrial approach.
Key Words: Pseudoaneurysm; Late left ventricular rupture; Mitral valve replacement; MRI to diagnose postoperative complications
|