ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2007;6:374-375. doi:10.1510/icvts.2006.150532
© 2007 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Yoshitaka Okamura
Takeshi Hiramatsu
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nishimura, Y.
Right arrow Articles by Iwahashi, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nishimura, Y.
Right arrow Articles by Iwahashi, M.
Related Collections
Right arrow Coronary disease
Right arrow Valve disease

Proposal for bail-out procedures - Valves

Apicoaortic valved conduit is a good alternative for aortic stenosis with porcelain aorta after off-pump coronary artery bypass grafting

Yoshiharu Nishimura*, Yoshitaka Okamura, Takeshi Hiramatsu and Masahiro Iwahashi

Department of Thoracic and Cardiovascular Surgery, Wakayama Medical University, Wakayama City, Wakayama, Japan

*Corresponding author. Tel.: +81-73-441-0615; fax: +81-73-446-4761.

E-mail address: nishim-y{at}wakayama-med.ac.jp (Y. Nishimura).

We report a case of aortic stenosis with porcelain aorta using an apicoaortic valved conduit after ‘aortic no touch’ off-pump coronary artery bypass grafting. Apicoaortic valved conduit is a good surgical option for this patient to avoid re-entry through the sternum, injury to patent graft and manipulation of the porcelain ascending aorta.

Key Words: Apicoaortic valved conduit; Porselain aorta; Off-pump coronary artery bypass grafting




This article has been cited by other articles:


Home page
ICVTSHome page
J. H. Chahine, I. El-Rassi, and V. Jebara
Apico-aortic valved conduit as an alternative for aortic valve re-replacement in severe prosthesis-patient mismatch
Interactive CardioVascular and Thoracic Surgery, October 1, 2009; 9(4): 680 - 682.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 European Association for Cardio-thoracic Surgery