ICVTS Click here to locate an Ethicon representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2007;6:200-203. doi:10.1510/icvts.2006.138503
© 2007 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Anil Bhan
Manju Gupta
Smartin Abraham
Rajesh Sharma
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bhan, A.
Right arrow Articles by Juneja, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bhan, A.
Right arrow Articles by Juneja, R.
Related Collections
Right arrow Congenital - acyanotic

Institutional report - Congenital

Surgical experience of aortopulmonary window repair in infants

Anil Bhan, Manju Gupta*, Smartin Abraham, Rajesh Sharma, Shyam Sunder Kothari and Rajnish Juneja

Departments of Cardiothoracic and Vascular Surgery and Cardiology, Cardiothoracic Center, All India Institute of Medical Sciences, New Delhi, India

*Corresponding author. Tel.: +91-9868301060.

E-mail address: drmgupta{at}hotmail.com (M. Gupta).

The aim of this study was to retrospectively analyze our results of both simple and complex aortopulmonary window (APW) repair in infants. From September 1994 to May 2003, 21 infants which included 15 with simple APW (weight 3.9±0.8 kg and age 5.1±3.7 months) and six with complex APW (weight 4.03±1.1 kg and age 5±3.8 months) underwent APW repair at the All India Institute of Medical Sciences, New Delhi, India. The approach for APW repair was ligation without CPB in four patients, division and suturing using CPB in one patient, trans-aortic with Goretex patch closure in 11 patients, trans-pulmonary in one patient and trans-window in four patients. The hospital mortality was 13% and 33% for simple and complex APW, respectively. On mean follow-up of 39 months there was no re-operation or late death. An early repair of APW is mandatory to achieve a good surgical result. Trans-aortic repair of APW is the procedure of choice for all APWs, except in the case of large defects where anterior sandwich patch technique (trans-window repair) may be done. In our view, simple ligation without CPB should be avoided due to the possibility of residual APW and distortion of pulmonary artery.

Key Words: Congenital heart disease; Conotruncal abnormalities; Pulmonary artery hypertension







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 European Association for Cardio-thoracic Surgery