ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2007;6:5-8. doi:10.1510/icvts.2006.137943
© 2007 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Enrico Ferrari
Piergiorgio Tozzi
Ludwig Karl von Segesser
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferrari, E.
Right arrow Articles by von Segesser, L. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferrari, E.
Right arrow Articles by von Segesser, L. K.

Work in progress report - Experimental

The Vascular Join: a new sutureless anastomotic device to perform end-to-end anastomosis. Preliminary results in an animal model{star}

Enrico Ferrari*, Piergiorgio Tozzi and Ludwig Karl von Segesser

Department of Cardiovascular Surgery, Centre Hôpitalier Universitaire Vaudois (CHUV), 46, rue du Bugnon, CH-1011 Lausanne, Switzerland

*Corresponding author. Tel.: +41 79 310 1386; fax: +41 21 314 2278.

E-mail address: enrico.ferrari{at}chuv.ch (E. Ferrari).

Standard vascular techniques don't meet new surgeons' needs for the more complex vascular reconstructions, minimal invasive approaches and robotic surgery. Therefore, alternative ways to perform vascular anastomosis are always welcome. We present a new sutureless vascular connector and the first animal study. The Vascular Join consists of two metallic rings fixed to the extremity of two conduits being joined together, connected with a snap-on system. The key element that makes this device different from all other sutureless devices is that there is no foreign material inside the vessel lumen. In 10 adult sheep, both carotid arteries were prepared and severed after heparinisation. Twenty end-to-end vascular anastomoses were performed and controlled with intravascular ultrasound and colour-Doppler. Animals were sacrificed and a histopathological analysis was carried out. All anastomoses were successfully completed without bleedings, stenosis or occlusions. The histological results confirmed the perfect vessel edges apposition and absence of foreign material in the vessel lumen. The intimal layer was intact. Vascular Join can easily perform sutureless end-to-end anastomoses and it can be used either with biological or prosthetic materials. Further animal studies are underway to assess the long-term results. Following the same technical criteria, we are developing an end-to-side anastomotic device.

Key Words: Vascular connector; Sutureless anastomosis; Suture technique







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 European Association for Cardio-thoracic Surgery