ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2006;5:637-639. doi:10.1510/icvts.2006.135087
© 2006 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Martin Oberhoffer
Calin Vicol
Bruno Reichart
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beiras-Fernandez, A.
Right arrow Articles by Reichart, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beiras-Fernandez, A.
Right arrow Articles by Reichart, B.
Related Collections
Right arrow History
Right arrow Valve disease

Follow-up papers - Cardiac general

34-Year durability of a DeBakey Surgitool mechanical aortic valve prosthesis

Andres Beiras-Fernandez*, Martin Oberhoffer, Felix Kur, Ingo Kaczmarek, Calin Vicol and Bruno Reichart

Department of Cardiac Surgery, University Hospital Grosshadern, Ludwig-Maximilians-University, Marchioninistrasse 15, 81377 Munich, Germany

*Corresponding author: Tel.: +49 89 70955633; fax: +49 89 70952635.

E-mail address: Andres.Beiras{at}med.uni-muenchen.de (A. Beiras-Fernandez).

Background: The DeBakey Surgitool mechanical aortic valve prosthesis was the first mechanical prosthetic valve in which pyrolitic carbon was used. This valve was on the market from 1969 to 1978 and approximately 3300 valves were implanted in this lapse worldwide. Report: We present a DeBakey Surgitool mechanical aortic valve prosthesis implanted in 1972, which has been functioning for almost 34 years and still presents a good performance. Comment: Spontaneous strut fractures associated with haemodynamic complications and death, even in asymptomatic patients, was the reason to withdraw this prosthetic valve from the market. However, a prophylactic replacement of DeBakey Surgitool valve was not indicated in our patient due to the excellent prosthesis compliance.

Key Words: Aortic valve replacement; Mechanical prosthesis; Durability; Surgitool DeBakey







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 European Association for Cardio-thoracic Surgery