ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2006;5:202-206. doi:10.1510/icvts.2005.126649
© 2006 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Andrew J. Lodge
Shu S. Lin
Carmelo A. Milano
Sinan A. Simsir
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Turek, J. W.
Right arrow Articles by Simsir, S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Turek, J. W.
Right arrow Articles by Simsir, S. A.
Related Collections
Right arrow Electrophysiology - arrhythmias
Right arrow Minimally invasive surgery

Institutional report - Arrhythmia

Histopathology and transmurality of acute microwave lesions on the beating human atrium

Joseph W. Tureka, Louis R. Dibernardob, Andrew J. Lodgea, Shu S. Lina, R. Duane Davisa, Carmelo A. Milanoa and Sinan A. Simsira,*

a Department of Surgery, Duke University Medical Center, Division of Cardiovascular and Thoracic Surgery, Durham, NC 27710, USA
b Duke University Medical Center, Department of Pathology, Durham, NC, USA

*Corresponding author. Tel.: +1-919-684-4694; fax: +1-919-681-7524.

E-mail address: sinan.simsir{at}duke.edu (S.A. Simsir).

Microwave energy allows thoracoscopic beating-heart ablation for the treatment of atrial fibrillation. However, there is a paucity of data on the histologic effects of microwave energy on the beating human heart. This study aims to histopathologically characterize microwave lesions on the beating human atrium. Microwave energy was applied prior to cardiectomy on the beating native right atrium in eight patients undergoing heart transplantation and as a circumferential left atrial ‘box’ lesion in one patient undergoing heart-lung transplantation. Lesions were applied following heparinization and cannulation, but before initiation of cardiopulmonary bypass. Following cardiectomy, specimens were resected, fixed and subjected to histologic preparation. Grossly, all atrial lesions were ‘comma-shaped’ with an area of maximum injury on the surface. Microscopically, myocyte injury manifested as acute coagulation necrosis with hypereosinophilic myocytes with both nuclear loss and pyknosis. Contraction bands were noted at the periphery of lesions. The injury was transmural in all right atrial lesions. The left atrial sample contained a circumferential lesion ranging from 0.1 to 0.8 cm in width. The cut edge demonstrated lesion depths of 0.2–0.6 cm, maximum (transmural) in the inferior margin. Microwave ablation represents an acceptable energy source to create characteristic lesions on the beating human atrium.

Key Words: Atrial fibrillation; Microwave ablation; Human atrium; Histopathology; Pulmonary veins