ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2006;5:183-186. doi:10.1510/icvts.2005.123372
© 2006 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Daniele Maselli
Francesco Musumeci
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maselli, D.
Right arrow Articles by Musumeci, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maselli, D.
Right arrow Articles by Musumeci, F.
Related Collections
Right arrow Cerebral protection
Right arrow Extracorporeal circulation
Right arrow Valve disease

Institutional report - Valves

Endovascular balloon versus transthoracic aortic clamping for minimally invasive mitral valve surgery: impact on cerebral microemboli

Daniele Masellia,*, Raffaella Piziob, Gabriele Borellia and Francesco Musumecib

a Cardio-Thoracic Department, U.O. Cardiochirurgia, Azienda Ospedaliera Universitaria Pisana, Via Paradisa no 2, 56124 Pisa, Italy
b Department of Cardiac Surgery, S. Camillo Hospital, Rome, Italy

*Corresponding author. Tel.: +39 050 995261; fax: +39 050 995271.

E-mail address: dmaselli{at}tiscali.it (D. Maselli).

To evaluate micro embolic events occurrence during minimally invasive mitral valve procedures, comparing balloon endovascular aortic occlusion (Group I) and transthoracic aortic clamping technique (Group II), 36 patients (20 in Group I and 16 in Group II) undergoing minimally invasive mitral valve surgery were selected by CT scan and Doppler studies for absence of atherosclerotic disease at aortic, coronary or peripheral level. Assignment to one of the two groups was made on the basis of surgeon's preference. Continuous automated intra-operative transcranial Doppler was used to monitor micro embolic events during five operative steps: cardiopulmonary bypass (CPB) setup, time interval from CPB start until aortic clamp positioning, first minute after clamp-on, first minute after clamp-off, first ten minutes after CPB weaning start. More embolic events were observed in Group II than in Group I (total 143.4±30.6 per patient vs. 78.9±28.6 per patient). A large amount of embolic events occurring mainly when the aortic clamp was positioned and released accounted for the observed differences. In a low risk population for embolic events occurrence, endovascular balloon aortic clamping determined less embolic signals than transthoracic aortic clamping.

Key Words: Minimally invasive surgery; Embolism







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 European Association for Cardio-thoracic Surgery