ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2005;4:391-395. doi:10.1510/icvts.2004.098160
© 2005 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow On-line Video
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Kazumasa Orihashi
Taijiro Sueda
Kenji Okada
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Orihashi, K.
Right arrow Articles by Hamamoto, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Orihashi, K.
Right arrow Articles by Hamamoto, M.
Related Collections
Right arrow Cardiac - other
Right arrow Congenital - acyanotic
Right arrow Minimally invasive surgery

Institutional report - Congenital

Real-time three dimensional echo-guided closure of atrial septal defect: an experimental model{star}

Kazumasa Orihashi*, Taijiro Sueda, Kenji Okada, Katsuhiko Imai, Koji Ban and Masaki Hamamoto

Division of Cardiovascular Surgery, Hiroshima University Hospital, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551, Japan

*Corresponding author. Tel.: +81-82-257-5216; fax: +81-82-257-5219.

E-mail address: orichan{at}hiroshima-u.ac.jp (K. Orihashi).

Real-time 3D echo may open the way to off-pump closure of an atrial septal defect with a robotic surgery technique without remnant of closure device. We report the preliminary results of 3D echo-guided closure of defect in an experimental model. A sheet with an oval defect immersed in water was visualized with 3D echo as well as surgical instruments. The defect was closed under echo guidance. Visualization of objects and instruments, and feasibility and problems of this technique were examined. The defect was visualized like an endoscopic view. Changing the view point without moving the transducer was a unique advantage. Visualization of instruments was acceptable with the lowest gain level. Acoustic shadow was helpful for comprehending the spatial relationship among the objects. Position of needle entry could be confirmed by the movement of the sheet. As the defect was sutured, fold convergence appeared on the sheet. Difficulties were encountered in passing the needle between instruments because of echo dropout. The string was poorly visualized. 3D echo-guided suturing was feasible with adequate image quality. However, an improvement of the surface of instruments and a wider scanning area is necessary for achieving surgical procedures with more safety and reliability.

Key Words: Atrial septal defect; Three-dimensional echo; Minimally invasive surgery







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 European Association for Cardio-thoracic Surgery