ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2005;4:267-271. doi:10.1510/icvts.2004.097246
© 2005 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Ad J.J.C. Bogers
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Kraker, M.
Right arrow Articles by Bogers, A. J.J.C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Kraker, M.
Right arrow Articles by Bogers, A. J.J.C.
Related Collections
Right arrow Mediastinum
Right arrow Minimally invasive surgery

Institutional report - Thoracic general

CT and myasthenia gravis: correlation between mediastinal imaging and histopathological findings{star}

Marjolein de Kraker1, Jolanda Kluin1,*, Nomdo Renken2, Alex P.W.M. Maat1 and Ad J.J.C. Bogers1

1 Department of Cardiothoracic Surgery, Erasmus MC, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands
2 Department of Radiology, Erasmus MC, Rotterdam, The Netherlands

*Corresponding author. Tel.: + 31- 647262040; fax: +31-104633993.

E-mail address: j.kluin{at}erasmusmc.n (J. Kluin).

The surgical strategy in patients with myasthenia gravis (MG) is influenced by the suspicion of thymoma based on mediastinal imaging. Aim of this retrospective study was to analyse the accuracy of CT of the mediastinum in predicting the histological findings in patients with MG referred for thymectomy. Thirty-four CT-scans of MG patients referred for thymectomy between October 1989 and October 2003 were retrospectively evaluated by three cardio-thoracic surgeons and three radiologists. Data were analysed by Kappa statistics to judge inter-observer variance and were compared to the histopathological findings to determine predictive value. Observer agreement among the radiologists was fair (Kappa=0.28) and among the cardio-thoracic surgeons slight (Kappa=0.08). The average negative predictive value of no thymoma on CT was 91% (range 78–100%). The average positive predictive of thymoma on CT value was only 39% (range 29–58%). The average sensitivity of CT imaging in the study population was 75% (range 25–100%) and the average specificity was 62% (range 42–81%). In patients with MG undergoing thymectomy, CT is helpful in detecting thymoma, but the high inter-observer variation indicates that it remains difficult to distinguish lymphoid follicular hyperplasia from thymoma. This will influence the surgical strategy in patients with myasthenia gravis.

Key Words: Myasthenia gravis; Computed tomography; Multiple observer agreement; Thymoma




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
H. El-Bawab, A. A. Al-Sugair, M. Rafay, W. Hajjar, M. Mahdy, and K. Al-Kattan
Role of flourine-18 fluorodeoxyglucose positron emission tomography in thymic pathology
Eur. J. Cardiothorac. Surg., April 1, 2007; 31(4): 731 - 736.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 European Association for Cardio-thoracic Surgery