ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Cornelius Borst
Paul F. Gründeman
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Budde, R. P.J.
Right arrow Articles by Gründeman, P. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Budde, R. P.J.
Right arrow Articles by Gründeman, P. F.
Related Collections
Right arrow Coronary disease
Right arrow Minimally invasive surgery
Interactive Cardiovascular and Thoracic Surgery 3:616-620(2004)
© 2004 European Association of Cardio-Thoracic Surgery


Institutional report - Experimental

Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses

Ricardo P.J. Budde, Thomas C. Dessing, Rudy Meijer, Patricia F.A. Bakker, Cornelius Borst and Paul F. Gründeman*

Heart Lung Center Utrecht, University Medical Center, Utrecht, The Netherlands

* Corresponding author. University Medical Center Utrecht, Room G02.523, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands. Tel.: +31-30-2507155; fax: +31-30-2522693. (E-mail: utrecht.cardioresearch{at}hli.azu.nl).

In totally endoscopic coronary artery bypass surgery, intra-operative assessment of anastomotic quality is needed. We evaluated the endoscopic application of epicardial ultrasound to visualize the coronary anastomosis and detect a construction error. In 8 pigs (71–78kg), 16 internal mammary artery to left anterior descending coronary artery anastomoses were constructed conventionally, either correctly (n=8) or incorrectly with a suture cross-over construction error (n=8). A 13MHz mini-transducer (15x9x6mm) was introduced through a port and manipulated by the ‘da Vinci’ system. The chest was re-opened and scanning repeated manually. Postoperatively, macroscopic inspection served as reference and the intra-operative ultrasound images were scored as ‘correct’ or ‘construction error’ by two blinded observers. All anastomoses were scored accurately by both observers. One anastomosis constructed to be correct was scored as construction error, due to narrowing of the outflow corner and anastomotic orifice. Ultrasound images corresponded with macroscopic inspection. Closed-chest scan time was about 1.5 times longer than open-chest scan time, 176s (88–464) (median, range) versus 125s (75–314) (P=0.01), respectively. Closed-chest epicardial 13MHz ultrasound scanning required a median of 3min and enabled discrimination between correctly and incorrectly constructed coronary anastomoses.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
R. P.J. Budde, P. F. A. Bakker, R. Meijer, C. Borst, and P. F. Grundeman
Ultrasound Mini-Transducer with Malleable Handle for Coronary Artery Surgery
Ann. Thorac. Surg., January 1, 2006; 81(1): 322 - 326.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 European Association for Cardio-thoracic Surgery