ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Rainer G. Leyh
Christian Hagl
Theo Kofidis
Axel Haverich
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leyh, R. G.
Right arrow Articles by Haverich, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leyh, R. G.
Right arrow Articles by Haverich, A.
Related Collections
Right arrow Cardiac - other
Right arrow Great vessels
Right arrow Valve disease
Interactive Cardiovascular and Thoracic Surgery 2:116-119(2003)
© 2003 European Association of Cardio-Thoracic Surgery


Institutional review - Valves

Impact of ascending aorta replacement combined with a Ross procedure on autograft root distensibility and function in patients with combined pathology of the aortic valve and ascending aorta

Rainer G. Leyh*, Christian Hagl, Theo Kofidis and Axel Haverich

Division of Thoracic and Cardiovascular Surgery, Hannover Medical School, Carl Neuberg Strasse 1, 30623 Hannover, Germany

* Corresponding author. Tel.: +49-511-532-6581; fax: +49-511-532-5404
leyh{at}thg.mh-hannover.de

In this study we aimed to assess the autograft root dimensions, distensibility, and autograft valve function in patients after Ross operation combined with replacement of the ascending aorta compared to patients that underwent Ross operation only. Forty patients received a Ross operation, and in 12 of them an additional replacement of the ascending aorta was performed. Autograft root dimensions, distensibility, and valve function were assessed by echocardiography. There were no differences in root size, distensibility, and valve function between groups. Our preliminary results indicate that replacement of the ascending aorta with a noncompliant prosthesis has no effect on the autograft root.

Key Words: Aneurysm; Autograft; Aortic valve; Aortic root