ICVTS Click here for other ICVTS advertising opportunities
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Rajwinder S. Jutley
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Glennie, S.
Right arrow Articles by Jutley, R. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Glennie, S.
Right arrow Articles by Jutley, R. S.
Related Collections
Right arrow Education
Interactive Cardiovascular and Thoracic Surgery 2:3-5(2003)
© 2003 European Association of Cardio-Thoracic Surgery


Institutional review - Cardiac general

Strength of wired sternotomy closures: effect of number of wire twists

Susan Glenniea, Duncan E.T. Shepherda,* and Rajwinder S. Jutleyb

a Department of Bio-Medical Physics and Bio-Engineering, University of Aberdeen, Foresterhill, Aberdeen, AB25 2ZD, UK
b Department of Cardiac Surgery, Nottingham City Hospital, Hucknall Road, Nottingham, NG5 1PB, UK

* Corresponding author. Tel.: +44-1224-553489; fax: +44-1224-685645
d.shepherd{at}biomed.abdn.ac.uk

The objective of this study was to investigate the effect of the number of wire twists on the strength of wired sternotomy closures. A custom-built test rig, fitted to a materials testing machine, was used to apply an increasing tension to wire closures, until they failed. The number of twists in the wire closure was varied between one and ten. Stainless steel wires of diameter 0.7 mm (No. 5) and 0.9 mm (No. 7) were tested. Initially, there is an increase in the maximum strength of the wire closure with increasing number of wire twists. After three wire twists greater strength is not achieved with increasing the number of wire twists. The highest mean force taken by the 0.7 mm diameter wire was 613 N ({approx}63 kg), at nine wire twists, whereas the highest force taken by the 0.9 mm diameter wire was 887 N ({approx}90 kg), at eight wire twists. However, by three wire twists, 80% and 88% of the maximum force has been achieved for the 0.7 and 0.9 mm diameter wire, respectively. Twisting wires many times in a sternotomy closure does not result in increased strength. Three or four twists would appear sufficient to sustain the forces across a sternotomy.

Key Words: Median sternotomy; Strength; Twists; Wire




This article has been cited by other articles:


Home page
ICVTSHome page
L. K. von Segesser
Enhanced virtual conferencing on ICVTS: introduction of DOIs makes eComments citable
Interactive CardioVascular and Thoracic Surgery, August 1, 2006; 5(4): 331 - 332.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Bruhin, U. A. Stock, J.-P. Drucker, T. Azhari, J. Wippermann, J. M. Albes, D. Hintze, S. Eckardt, C. Konke, and T. Wahlers
Numerical Simulation Techniques to Study the Structural Response of the Human Chest Following Median Sternotomy