© 2002 European Association of Cardio-Thoracic Surgery
Simple method for monitoring hand perfusion following radial artery harvest for coronary artery bypass graftingDivision of Cardiac Surgery, Royal Victoria Hospital, Belfast BT12 6BA, Northern Ireland, UK
* Corresponding author. Tel.: +44-2890-240503, ext. 3500; fax: +44-2890-894918 The ever increasing use of the radial artery (RA) as a coronary bypass conduit raises concerns regarding potential local complications following RA harvest in particular hand ischaemia. Transcutaneous pulse oximetry provides a simple non-invasive objective assessment of collateral ulnar blood flow thus providing adequate continuous monitoring of hand perfusion in the early post-operative phase following RA procurement.
Key Words: Radial artery harvest; Pulse oximetry; Hand perfusion
|